Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger

ERKUTAY, TASDEMIRCI and ERTAN, ALPTEKIN and MURAT, HOSOZ (2016) Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger. In: Fourth International Conference on Advances in Mechanical and Robotics Engineering - AMRE 2016, 15-16 December 2016, Rome, Italy.

[img]
Preview
Text
20161226_122817.pdf - Published Version

Download (772kB) | Preview
Official URL: https://www.seekdl.org/conferences/paper/details/8...

Abstract

In this study an experimental system was set up from the original components of an automotive air conditioning (AAC) system. After than internal heat exchanger (IHX) and reversing valve were installed to use as heat pump and improve performance of it. For each mode of operations, the system was tested at five different compressor speeds between 800 and 2800 rpm with intervals of 400 rpm. In the heat pump mode operations without IHX, the temperatures of the air streams entering the evaporator and condenser were maintained at Tevap,ai=0°C – Tcond,ai=0°C, Tevap,ai=10°C –Tcond,ai=10°C and Tevap,ai=15°C – Tcond,ai=15°C. IHX was started up the temperatures of the air streams at the inlets of the evaporator and condenser were maintained at Tevap,ai=5°C – Tcond,ai=5°C, Tevap,ai=10°C –Tcond,ai=10°C and Tevap,ai=15°C – Tcond,ai=15°C. Using experimental data, performance parameters such as conditioned air stream temperature, compressor power, compressor mechanical power and compressor discharge temperature were evaluated. In heat pump mode provided enough heating capacity and conditioned air stream temperatures even at low compressor speeds. Furthermore, the heating capacity increased but COPh decreased with rising compressor speed however compressor power decreased and COPc increased with using IHX.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: HFC134a, automotive air conditioning, internal heat exchanger.
Depositing User: Mr. John Steve
Date Deposited: 18 Mar 2019 08:45
Last Modified: 18 Mar 2019 08:45
URI: http://publications.theired.org/id/eprint/590