Optimal design criterion for Heat Transformer operating with Water/Carrol

C.V., VALDEZ-MORALES and R.J., ROMERO (2016) Optimal design criterion for Heat Transformer operating with Water/Carrol. In: Fourth International Conference on Advances in Mechanical and Automation Engineering - MAE 2016, 18-19 August 2016, Rome, Italy.

[img]
Preview
Text
20160908_120409.pdf - Published Version

Download (735kB) | Preview
Official URL: https://www.seekdl.org/conferences/paper/details/8...

Abstract

This paper shows a discussion for selection of thermodynamic operating conditions in an absorption heat transformer (AHT). An AHT is the only thermal machine that increases the source temperature using heat for does it with a negligible mechanical energy. Thermodynamic parameters for AHT are the same than for heat pumps: Coefficient of performance (COP) and Gross Temperature Lift (GTL). Those parameters are not linearly correlated. Instead GTL increases its value when COP decrease. The criterion for an optimal design is based on an objective function with COP and GTL. This paper use AHT thermodynamic data operating with Carrol – water for show the best design operating conditions.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Thermodynamic design, coefficient of performance, Carrol – water, thermal machines, gross temperature lift
Depositing User: Mr. John Steve
Date Deposited: 22 Mar 2019 06:59
Last Modified: 22 Mar 2019 06:59
URI: http://publications.theired.org/id/eprint/764