Comparison of percentage of Daylight Factor values (%DF) from field work to alternative methods of similar derivations

ADEL, ABDULLAH and SHARIFAH FAIRUZ SYED, FADZIL (2016) Comparison of percentage of Daylight Factor values (%DF) from field work to alternative methods of similar derivations. In: Fifth International Conference On Advances in Applied Science and Environmental Engineering - ASEE 2016, 12-13 March,2016, Kuala Lumpur, Malaysia.

[img]
Preview
Text
20160321_111218.pdf - Published Version

Download (858kB) | Preview
Official URL: https://www.seekdl.org/conferences/paper/details/7...

Abstract

Field work measurement in the East room from previous work were found to be 2.28% with a wall to window ratio (WWR) of 50% and a %DF of 1.23% for a modified WWR of 25%. This paper examines the extent of the field work %DF values compared to the %DF values that could be derived for similar cases while using alternative methods. The alternative methods include Building Research Station (BRS) protractors and three other simulation software including ECOTECT, IES and ReLux. Results found that the %DF differences between field work values and the alternative methods were minimal. This proves that the %DF method is still a very reliable method for daylight assessment

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Daylight factor %DF, Window to wall ratio (WWR), Building Research Station protractors (BRS), ECOTECT, IES<VE> and ReLux